Download
CSI Formatted Specifications as a MS Word Document
or Adobe PDF
FabriTRAK®
UPHOLSTERED WALL SYSTEM
Section 09840
- GENERAL
- Scope
- Furnish and install
FabriTRAK® Wall
System as manufactured by FabriTRAK®
SYSTEMS, INC. and as required by the Contract Documents.
- Related Work Elsewhere
- Preparation of smooth,
flat and plumb substrate.
- Architectural Woodwork,
Masonry, Doors and Frames, Hardware, Gypsum Drywall, Plastering,
Ceilings, Wall Covering Painting and Electrical Work.
- Standards
- The system shall consist
of site installed and fabricated, concealed FabriTRAK®
System as manufactured by FabriTRAK®
SYSTEMS, INC. 877-322-7487 (USA only), 732-432-5860 (USA &
International), 877-829-2550 (Canada only). The acoustical or tackable
wall treatment system shall have a Fire Hazard Classification of
Class 1 or A when tested in accordance with ASTM E-84 or UL 723.
- Qualifications
- The installation work
of this Section shall be performed by an authorized dealer, licensed
by the manufacturer, and shall be a member of the Wall Upholstery
Guild of America (W.U.G.A.) and shall be certified as such.
- Submittals
- Submit manufacturer's
product specifications and such other data as may be required to
show compliance with the Contract Documents. Submit in writing to
the Owner, through the Architect, the manufacturer's dealer certification.
Submit installation Dealer's five year Limited Warranty against
defects in the FabriTRAK®
materials and workmanship. Submit sample of fabric (at least 12"
x 12"). Submit samples of the stretching system. Submit core samples.
- Product Handling
- Store all materials
off the ground and protected from dirt and dust of construction
operations. Handle materials in a manner that will protect them
from damage and soiling.
- Products
- The System Components shall
consist of the following:
- FabriTRAK®
rigid vinyl framework with clamping jaws, one-piece section
- Edge profile:
- As selected by
architect.
- Core:
- As selected by
architect.
- Fabric:
- Standard panel
fabric, as selected by Architect.
- Existing Conditions
- Examine the condition
of the substrate and the conditions under which the work of the
Section is to be performed. Notify the Contractor in writing or
any unsatisfactory conditions. Do not proceed with the work until
unsatisfactory conditions have been corrected in a manner satisfactory
to the installer. Do not install acoustical wall panel fabric in
any space until:
- Installation
- Apply the FabriTRAK®
framework in the areas to receive the acoustical wall treatment
as shown on the drawings. Secure the framework with suitable fastening
devices.
- Install the framework
plumb and straight, flush in proper alignment.
- Install the core, continuous
and flush, to the shoulder of the track.
- Cut the fabric from
each roll marking and maintaining sequence drops and matching direction
weave for
- The fabric shall be
stretched tautly, evenly and smoothly and be free of defects and
flaws.
- No stapling or gluing
of fabric to cores or channels will be permitted.
Download
CSI Formatted Specifications as a MS Word Document
or Adobe PDF